[CRTech] Christian Radio Tech [MSG 83612]
[Thread Prev] [-- Thread Index --] [Thread Next] [Date Prev] [-- Date Index --] [Date Next]
Re: Burk Plus Touch features
To: CRTech <crtech@crtech.org>
Subject: Re: Burk Plus Touch features
From: Willie Barnett <wbradiolists@gmail.com>
Date: Fri, 24 Aug 2018 12:51:37 -0400
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:in-reply-to:references:from:date:message-id:subject:to; bh=Ni1bjWL0Mhe73OE0B2z1oM5zMB6WGy8uDViOw4RH3Wg=; b=u1fK8L8gf3wf/+qEirqV1wNP+8IjWKBRvZn66KR4PpvSyznySv9YRyjGDuKz9r6uyq f6Nu0F8FzJcaX5s+VVywCuiswOD5DeUgUt9N6eqRn2gFHyTrfAPyBhibCNMpu3ckIWiZ 76vSnnIxmL0XFeQC6QwGzSUcX/d68YT4MkMrBffCFIWeYh3I38KD/+ezhiF5jmY1PHje 7QJFPqsmHU4h4HSAYFVepFv/y4pqKc0NIRxUYGKGQMBgi0yluFyecBB1y819v83O9t2T 7LdT+lfuy/aPw9+6QRhWiNQKz5kwShWeOOKinBdZw2krULVKgwL5nSxvwcATJhSZi3MN 8ZCg==
In-reply-to: <CAB42DVpgHKGKNsMKzeDinEumo4iiEP3GBwXNwqDU=bmUfVe92g@mail.gmail.com>
References: <CAOkhgWqiU2Rg6XvRa8SK7HrPa4stEa0OZmfQeWPo5bZrt+Ctrw@mail.gmail.com> <CAB42DVpgHKGKNsMKzeDinEumo4iiEP3GBwXNwqDU=bmUfVe92g@mail.gmail.com>
This has that same feature, however, that would completely render our "oops-proof" system useless.

To explain: the ability to switch transmitters is controlled by pressing AND HOLDING a button on the legacy R/C system for 5 seconds. This completely prevents "OOOPS! I didn't mean to do that!"

Setting the momentary delay to 5 seconds... well, you see where THAT'S going? Accidental click = 5 seconds relay hold time, and "Poof!" we're off the air. Oops-proof system, useless. Not good.

If the relay follows the button, then an accidental click does nothing. Otherwise, "Are you sure?" can be activated, but it affects EVERYTHING, and that's nuts. ;)

Willie...


On Fri, Aug 24, 2018 at 12:32 PM, Tom Van Gorkom <tomvangorkom@gmail.com> wrote:
Yes, that is a useful feature, especially if programmable.  I use a timed relay feature in my Davicom units when rebooting some piece of equipment or holding a solenoid valve open for a certain amount of time. They have a programmable feature for setting a time duration (Pulse width) for momentary contact closures/opennings from 100 ms to hours. I use such a feature automatically for the most part except for a reboot of a router or something. In that case I made a button on my screen control panel to activate the relay pulse width set to 10 seconds. Just click it and it does the rest.

Tom Van Gorkom
References: Burk Plus Touch features
(Willie Barnett <wbradiolists@gmail.com>, 24 Aug 2018 16:03:48 -0000)
Re: Burk Plus Touch features
(Tom Van Gorkom <tomvangorkom@gmail.com>, 24 Aug 2018 16:32:35 -0000)
Prev by date: Re: Burk Plus Touch features
(Tom Van Gorkom, 24 Aug 2018 16:32:35 -0000)
Next by date: RE: Looking for a Marti Transmitter
(Bill, 25 Aug 2018 22:39:02 -0000)
Prev by thread: Re: Burk Plus Touch features
(Tom Van Gorkom, 24 Aug 2018 16:32:35 -0000)
Next by thread: Re: Burk Plus Touch features
(Kevin Kidd, 26 Aug 2018 15:16:53 -0000)
CRTech.org