RE: Meter probes, long/durable
To: CRTech <crtech@crtech.org>
Subject: RE: Meter probes, long/durable
From: Jesse Ruggles <Jesse.Ruggles@moody.edu>
Date: Fri, 27 Jul 2018 17:39:05 +0000
Accept-language: en-US
Authentication-results: spf=pass (sender IP is 66.185.255.157) smtp.mailfrom=moody.edu; crtech.org; dkim=none (message not signed) header.d=none;crtech.org; dmarc=bestguesspass action=none header.from=moody.edu;
Content-language: en-US
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=moodybibleinstitute.onmicrosoft.com; s=selector1-moody-edu; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=a+JRa9wPZ2ejKyrIrFlnEj/o2/gEOVKTT0sQrSdwc0E=; b=V68WXh8qyMZrcgGoI4J8XFVN3fnjHc4T28Me2aQWdQXraG3AVFRefxvgyZ7SYCe3iFAEX+kwM9wkdIuQYoGvgiFj3Luaoy8gngpVIU0Inzh3kXvygkc7CWTVzTZO0rsI4griiY2dXBnEMh0BbOdKP8nL0siCscyPjTo52ry6VAY=
In-reply-to: <CAOkhgWqWiQzdNTthoovf+qZDjm_2k-fMv+zWthx-c7ONy4KWhQ@mail.gmail.com>
References: <CAOkhgWq+bn6MUv6kSXKRAy40ua5nMX_pEKFm-4NymwOQGs1aPw@mail.gmail.com> <103a4181666142f795991b7f72999260@ex13prd01.moody.edu> <CAOkhgWqWiQzdNTthoovf+qZDjm_2k-fMv+zWthx-c7ONy4KWhQ@mail.gmail.com>
Spamdiagnosticmetadata: NSPM
Spamdiagnosticoutput: 1:99
Thread-index: AQHUJcbwZ24eYpCNYk+dGNlt2NgbyaSjUGwQgABXEwD//6xfMA==
Thread-topic: [CRTech] Meter probes, long/durable

I feared such a response, and sought guidance from the great and wise Google.

 

How ‘bout these?

 

https://www.fluke.com/en-us/product/accessories/clips/fluke-ac283

 

 

cid:image001.png@01D2971C.B25418E0

 

Jesse Ruggles
Assistant to the Director of Engineering  |  Broadcasting
O: (312) 329-2043

C: (954) 562-6965

 

820 N. LaSalle Blvd., Chicago, IL 60610
moodyradio.edu

 

From the Word to Life

 

From: Willie Barnett [mailto:wbradiolists@gmail.com]
Sent: Friday, July 27, 2018 12:31 PM
To: CRTech <crtech@crtech.org>
Subject: Re: [CRTech] Meter probes, long/durable

 

Fascinating! (in Mr Spock's voice)

Won't work, tho. It is used for reaching down into assembled units, to grab the leads on resistors to get voltage readings. The extra plastic "nib" on the end of this would definitely be in the way.

Willie...

 

On Fri, Jul 27, 2018 at 1:25 PM, Jesse Ruggles <Jesse.Ruggles@moody.edu> wrote:

Not quite the same, but the nearest thing I’ve used (other than the shorter clips similar to the 4565) are these:

https://www.grainger.com/product/GRAINGER-APPROVED-1000VAC-DC-PA6-Test-Probe-4WRA3?searchBar=true&searchQuery=4WRA3

Follow-Ups: Re: Meter probes, long/durable
(Willie Barnett <wbradiolists@gmail.com>, 27 Jul 2018 17:51:59 -0000)
References: Meter probes, long/durable
(Willie Barnett <wbradiolists@gmail.com>, 27 Jul 2018 16:28:51 -0000)
RE: Meter probes, long/durable
(Jesse Ruggles <Jesse.Ruggles@moody.edu>, 27 Jul 2018 17:25:20 -0000)
Re: Meter probes, long/durable
(Willie Barnett <wbradiolists@gmail.com>, 27 Jul 2018 17:31:26 -0000)
Prev by date: Re: Meter probes, long/durable
(Willie Barnett, 27 Jul 2018 17:31:26 -0000)