RE: HT-10 Blower Motor
To: Eric Send <erics@wtcmradio.com>, CRTech <crtech@crtech.org>
Subject: RE: HT-10 Blower Motor
From: Scott Todd <stodd@kloveair1.com>
Date: Mon, 23 Jul 2018 23:25:52 +0000
Accept-language: en-US
Authentication-results: spf=none (sender IP is ) smtp.mailfrom=stodd@kloveair1.com;
Content-language: en-US
Dkim-signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=corpemf.onmicrosoft.com; s=selector1-kloveair1-com; h=From:Date:Subject:Message-ID:Content-Type:MIME-Version:X-MS-Exchange-SenderADCheck; bh=0g9rpMKnRr1bLG2T6IKtoP4//MHFUyj6XnTEULesRsA=; b=BcAXFBuAuVgferYO54dXiL3Nm7udGn/9hdHenbGx5K2PIhEdPf63vkhb21+0vt2L/aqmOAYwLTwk3G3eN0IuL5BIEjID3/ssCyS2IGLoFyguA2NLX0ci3aCOfmFvVX4Q8A4W1s0VyCPc5UxLPm2TH38DViGp2I+KmwIU6edHjhE=
In-reply-to: <DM5PR08MB2953F68F95709D3052695BA7A7560@DM5PR08MB2953.namprd08.prod.outlook.com>
References: <DM5PR08MB2953F68F95709D3052695BA7A7560@DM5PR08MB2953.namprd08.prod.outlook.com>
Spamdiagnosticmetadata: NSPM
Spamdiagnosticoutput: 1:99
Thread-index: AQHUIsFCsR3NudPh1UyY9pzui6DKJ6Sdc0KQ
Thread-topic: HT-10 Blower Motor

A few hundred bucks at most to get the bearings replaced at a motor shop.  Likely it’ll be done in a day or two.

 

Scott Todd

 

From: Eric Send [mailto:erics@wtcmradio.com]
Sent: Monday, July 23, 2018 2:31 PM
To: CRTech <crtech@crtech.org>
Subject: HT-10 Blower Motor

 

I have a Harris HT-10 transmitter that has a tired blower motor. I am hearing bearing noise coming from the blower. The transmitter has been in service since 1993 and I have an even older HT-10 in service at another facility. Gates Air wants almost 4200.00 for a replacement motor. The lead time is four weeks. I was able to do some research and found a vendor that will sell me a blower for 2400.00 with about the same lead time. 

Still way to much $$$$.

Here is my question for the brain trust. 
Does anyone have a spare motor sitting on a shelf that are willing to part with for a reasonable amount?
Has anyone successfully rebuilt the original blower motor?
Has anyone successfully retrofitted a different less costly blower into an HT-10? 

Eric 
WTCM Radio
Traverse City, Mi 

BLOWER 230V 50/60 HZ
3220RPM, 525CFM, 410W |
ROTRON CX33A3G (DISTR #027555 (OBS)) | 
AMETEK-ROTRON 037792 (MODEL #NC33A3G)

Follow-Ups: Re: RE: HT-10 Blower Motor
(Mark Croom <markc@newmail.kinshipradio.org>, 24 Jul 2018 04:01:09 -0000)
References: HT-10 Blower Motor
(Eric Send <erics@wtcmradio.com>, 23 Jul 2018 19:30:59 -0000)
Prev by date: Overheating Problem
(Jim McDermott, 23 Jul 2018 23:14:47 -0000)
Next by date: Re: Overheating Problem
(Mark, 23 Jul 2018 23:30:52 -0000)
Prev by thread: HT-10 Blower Motor
(Ed Trombley, 24 Jul 2018 04:25:02 -0000)
Next by thread: Re: RE: HT-10 Blower Motor
(Mark Croom, 24 Jul 2018 04:01:09 -0000)
CRTech.org