RE: Best way to handle poor electric delivery
To: CRTech <crtech@crtech.org>
Subject: RE: Best way to handle poor electric delivery
From: Don Parker <Don@wljn.com>
Date: Wed, 5 Apr 2017 17:56:26 +0000
Accept-language: en-US
Content-language: en-US
In-reply-to: <MWHPR20MB16464E2CDEF632DC208F35E9B40A0@MWHPR20MB1646.namprd20.prod.outlook.com>
References: <MWHPR20MB16464E2CDEF632DC208F35E9B40A0@MWHPR20MB1646.namprd20.prod.outlook.com>
Thread-index: AdKuHx1Fu+NFmhClSHaajsFNwjM3AAAEpOsw
Thread-topic: Best way to handle poor electric delivery

Just came from a Grounding site seminar by Transtector;   I also know a site similar to what you are describing,  don’t trust your ground system , check it with a ground restiance tester.

A real one, not an ohm meter.  The site I am referring  power co. has  3 xfmers , and 3 wires feeding  a 1000 ft tower tx. Site . bad electrical issues until they , meaning tower owner , pounded in a 4 inch steel well casing

180 ft. down  I think to water table  , grounded tower to that well casing , and all is well.  

No , even  70 ft. ground rods still don’t work when they are in sandy soil , unless they ‘hit something to Bite  {conduct }  into .   Power Co. tried that, and it   didn’t work .

Chemical ground rods are recommended by ground specialist if no ground is possible to obtain  [expensive, and require maintenance]  Ufer grounds are also viable in dry places  of the world ,

 

That’s the news from northern Michigan beach sand county,    

            Don Parker    WLJN/WLJW GNMinc.   WD8RNZ

 

 

 

From: Solomon Bachman [mailto:sbachman@kcbi.org]
Sent: Wednesday, April 05, 2017 11:25 AM
To: crtech@crtech.org
Subject: [CRTech] Best way to handle poor electric delivery

 

Hey All,

 

I’d like to get some suggestions on cleaning up 3 Phase power in the middle of nowhere coming from a co-op. I have surge suppression on the mains and under the breaker with the transmitter but I am still cooking the input side of the 2500w modular power supplies every time there is storm.

 

The large surge suppressor on the incoming electric is older, so I am looking at replacing that since it is probably past its prime in surge dissipation. Are there any other tips/tricks/devices I should look at?

 

Solomon N Bachman | Chief Engineer

 

KCBI 90.9 FM  |  Dallas-Fort Worth

Encouraging Music…Words of Hope

750 N Saint Paul St.

Suite 1050

Dallas, TX 75201

www.kcbi.org

 

O | 469.801.7022

C | 817.523.9523

F | 214.468.9164

 

Follow-Ups: RE: RE: Best way to handle poor electric delivery
("Bill Hurne" <billhurne@pilgrimradio.com>, 5 Apr 2017 18:14:29 -0000)
References: Best way to handle poor electric delivery
(Solomon Bachman <sbachman@kcbi.org>, 5 Apr 2017 15:24:55 -0000)
Prev by date: Re: Phasing Issues?
(Robert Chrysafis, 5 Apr 2017 17:45:07 -0000)
Next by date: RE: RE: Best way to handle poor electric delivery
(Bill Hurne, 5 Apr 2017 18:14:29 -0000)
Prev by thread: Re: Re[2]: Best way to handle poor electric delivery
(tcowan, 6 Apr 2017 02:54:34 -0000)
Next by thread: RE: RE: Best way to handle poor electric delivery
(Bill Hurne, 5 Apr 2017 18:14:29 -0000)
CRTech.org